28-6-2011 28 033000=13069F
7. If you want to turn zone 31 into an emergency sensor, enter 31 on the number pad and
press OK. Zone number 31 will start flashing.
8. If you also want to turn zone 5 into an emergency sensor, enter 5 on the number pad and
press OK. Zone number 5 will start flashing.
9. If you want to turn zone 31 into a normal sensor again, enter 31 on the number pad and
press OK. Zone 31 will stop flashing.
10. Press CLEAR again to quit the menu.
Make sure the DS18 Door/Window Sensor is set to MIN if you want the message to be passed
on without a delay (see 8.1). Same applies for Motion Sensors on zone 15 and/or 16.
9.6 Sensor 27-32 ON/OFF
Used for setting zone 27 to 32 sensors to send Home Automation ON or OFF commands on
House Code +1 and Unit Code 7-12, in respond to alarm triggers from sensors registered to
respective zones 27-32 (e.g. zone 27 is related to UC 7, 29 to 9 etc). At present in this mode
(menu options) you see the installed sensors in zones 27-32 only as numbers round the side of
the display, just like for setting sensor mode. When entering the Sensor Zone number followed
by ON or OFF the respective Zone number around the edge flashes to indicate it has been set
to send a X10 Home Automation command which is either ON or OFF depending on the
choice made.
9.7 Deregistering a Door/Window or Motion Sensor
1. To access the menu, press the menu UP or menu DOWN button. The display now shows
ENTER PIN.
2. Enter your 4-digit PIN code (factory setting 0000. See 8.3 for changing the PIN code). The
display is cleared and shows a * for each number entered.
3. When the PIN code has been entered correctly, the word INSTALL will show up on the
display.
4. Press OK.
5. Enter the number of the zone you want to erase on the number pad and press CLEAR.
6. You are asked to confirm CLEAR ZONE 1. YES 2. NO.
7. Press 1 to erase the zone. The zone number is shown on the display.
8. Press CLEAR again to quit the menu.
Zones 31 and 32 can not be erased.
9.8 Power Failure Alarm: When the system is in armed mode, and there may occur a mains
power failure which lasts for at least 15 minutes, the console will dial out and give a message
POWER FAILURE
10. Advanced Home Automation functions
Chapter 7 described the use of X10 Home Automation options of the security system. But there
is more; besides the Plug & Play modules a large number of built-in switches, in-wall and sun
blind switches, remote controls and special modules are available. With the addition of these
modules you can control nearly everything that is electrically powered in your home via your
security system Base Console. See www.bmbelectronics.eu
(Product group Home
Automation) for more information.
The system has for default a few extra functions that use the X10 system:
10.1 Checking the status of the security system
Set a X10 module to address B4 (=HC+1, UC=4). This Home Automation module is now
automatically switched on as soon as the security system is activated. When the system is
disarmed, the module will also be switched off. Example: You can connect a table lamp to
this X10 module. If the system is activated, this lamp is always turned on. This means you can
instantly see if the system is activated when you are outside.